YASNAC MX3 PARAMETER REFERENCE LIST

Parameter #    

Description

Settings

Setting 6219

Parameter write enable switch

1 to change parameter s 0 to lock parameters

6004 D3

Programs O8000 - O8999 can be edited only when

6004 -D4 is set to 0

6004 D3

These programs can be displayed only when

6004 -D3 is set to 0

6006 D0

Enables automatic coordinate system setting

6006 -D0 is set to 1

 

Disables automatic coordinate system setting
(Also refer to # 6015 and # 6630 - # 6639)

6006 -D0 is set to 0

6006 D2

Rapid Rate in dry run mode

6006 -D2 is set to 1

 

Jog feed in dry run mode

6006 -D2 is set to 0

6007 D7

Reset is not required after editing

6007 -D2 is set to 1

 

Reset is required after editing

6007 -D2 is set to 0

6008 D5

O number is changeable with alt command

6008 -D5 is set to 1

 

O number is not changeable with alt command

6008 -D5 is set to 0

6015 D0 - D4

Automatic coordinate system setting is on

6015 - D is set to 1

 

Automatic coordinate system setting is off - X=D0, Y=D1, Z=D2, 4th=D3, 5th=D4

6015 - D is set to 0

6021 D2

Same prog is displayed when power is turned off

6021- D2 is set to 1

 

Displayed Prog. O0 when power is turned on

6021 -D2 is set to 0

6021 D0

Sees M2, M30, M99 as end of program

6021 -D0 is set to 1

 

does not see M2, M30, M99 as end of program

6021 -D0 is set to 0

6021 D6

writes over program in memory when loading by RS232

6021 - D6 is set to 1

 

"Already in" alarm happens when loading by RS232

6021 - D6 is set to 0

6021 D7

Programs O9000 - O9999 can be edited only when

6021 - D7 is set to 0

6022 D5

These programs can be displayed only when Parameter

6022 - D5 is set to 0

6022 D6

Enables binary search in edit / memory mode

6022 - D6 is set to 1

6066 D6

At power on control will be in M97

6066 -D6 is set to 1

 

At power on control will be in M96

6066 - D6 is set to 0

6304

X Axis zero return grid shift amount, 6305 Y, 6306 Z, 6307 4th, 6308 5th

 

6400

X Axis backlash amount, 6401Y, 6402 Z, 6403 4th, 6404 5th

 

6630

X Axis inch value for Automatic coordinate system setting 6631 Y, 6632 Z, 6633 4th, 6634 5th

 

6636

X Axis metric value for Automatic coordinate system setting 6337 Y, 6338 Z, 6339 4th, 6340 5th