509-467-3358 509-467-9829 Fax service@mts-nw.com
YASNAC MX3 PARAMETER REFERENCE LIST
|
Parameter # |
Description |
Settings |
|
Setting 6219 |
Parameter write enable switch |
1 to change parameter s 0 to lock parameters |
|
6004 D3 |
Programs O8000 - O8999 can be edited only when |
6004 -D4 is set to 0 |
|
6004 D3 |
These programs can be displayed only when |
6004 -D3 is set to 0 |
|
6006 D0 |
Enables automatic coordinate system setting |
6006 -D0 is set to 1 |
|
Disables automatic coordinate system
setting |
6006 -D0 is set to 0 |
|
|
6006 D2 |
Rapid Rate in dry run mode |
6006 -D2 is set to 1 |
|
Jog feed in dry run mode |
6006 -D2 is set to 0 |
|
|
6007 D7 |
Reset is not required after editing |
6007 -D2 is set to 1 |
|
Reset is required after editing |
6007 -D2 is set to 0 |
|
|
6008 D5 |
O number is changeable with alt command |
6008 -D5 is set to 1 |
|
O number is not changeable with alt command |
6008 -D5 is set to 0 |
|
|
6015 D0 - D4 |
Automatic coordinate system setting is on |
6015 - D is set to 1 |
|
Automatic coordinate system setting is off - X=D0, Y=D1, Z=D2, 4th=D3, 5th=D4 |
6015 - D is set to 0 |
|
|
6021 D2 |
Same prog is displayed when power is turned off |
6021- D2 is set to 1 |
|
Displayed Prog. O0 when power is turned on |
6021 -D2 is set to 0 |
|
|
6021 D0 |
Sees M2, M30, M99 as end of program |
6021 -D0 is set to 1 |
|
does not see M2, M30, M99 as end of program |
6021 -D0 is set to 0 |
|
|
6021 D6 |
writes over program in memory when loading by RS232 |
6021 - D6 is set to 1 |
|
"Already in" alarm happens when loading by RS232 |
6021 - D6 is set to 0 |
|
|
6021 D7 |
Programs O9000 - O9999 can be edited only when |
6021 - D7 is set to 0 |
|
6022 D5 |
These programs can be displayed only when Parameter |
6022 - D5 is set to 0 |
|
6022 D6 |
Enables binary search in edit / memory mode |
6022 - D6 is set to 1 |
|
6066 D6 |
At power on control will be in M97 |
6066 -D6 is set to 1 |
|
At power on control will be in M96 |
6066 - D6 is set to 0 |
|
|
6304 |
X Axis zero return grid shift amount, 6305 Y, 6306 Z, 6307 4th, 6308 5th |
|
|
6400 |
X Axis backlash amount, 6401Y, 6402 Z, 6403 4th, 6404 5th |
|
|
6630 |
X Axis inch value for Automatic coordinate system setting 6631 Y, 6632 Z, 6633 4th, 6634 5th |
|
|
6636 |
X Axis metric value for Automatic coordinate system setting 6337 Y, 6338 Z, 6339 4th, 6340 5th |